Difference between revisions of "MansOS Humidity"
| Line 1: | Line 1: | ||
__TOC__ |
|||
mos/hil/humidity.h |
mos/hil/humidity.h |
||
Revision as of 19:42, 14 November 2011
mos/hil/humidity.h
Usage and configuration
To use humidity sensor, make the following changes to you application:
- enable humidity sensor by adding the following line to config file:
USE_HUMIDITY = y
- If using generic MSP430 platforms, which use the same humidity sensor as TelosB, additional definition in config file required:
USE_TELOSB_HUMIDITY = y
- in your code, call humidityOn() to turn the sensor on
- in your code, call readHumidity() to get 16-bit raw humidity value
Function reference
All platform-independent humidity sensor functions are described in mos/hil/humidity.h . Implementation can be found under mos/hal/platforms/<platform-name>/
void humidityInit(); // init humidity sensor, do not turn it on - called by kernel automatically, not needed in application cod void humidityOn(); // turn on humidity sensor void humidityOff(); // turn off humidity sensor uint16_t readHumidity(); // read humidity value // Optional - some humidity sensors (SHT11) also provide temperature reading uint16_t readHTemperature(); // read temperature value from humidity sensor
Example application:
//----------------------------------------------------
// Read humidity sensor, print raw value to UART
//----------------------------------------------------
#include "stdmansos.h"
#include "dprint.h"
#include "humidity.h"
//-------------------------------------------
// Entry point for the application
//-------------------------------------------
void appMain(void)
{
PRINT_INIT(129);
PRINTF("Humidity test app\n");
humidityOn();
while (1) {
sleep(1);
uint16_t hum_raw = readHumidity();
uint16_t temp_raw = readHTemperature();
PRINTF("hum = %i\t temp = %i\n", hum_raw, temp_raw);
}
}